15 Years In The Business Of Designing & Manufacturing Energy Consumption Monitors !

 

 

ECM-1220 PRO Accessories

  WPA-3 Wall Plug Adaptor
  • Male-Female Outlet adaptor with Loop for Split-Core or Clamp-On CT Access to Line Conductor
  • One WPA-3 is included in the ECM-1220 PKG, however, and additional WPA-3 is required for monitoring two wall-plugged loads at the same time.

SPLIT-15 Split Core Current Transformer

  • 15A. Max Split-Core CT is recommended for "low current" applications.

  • Special Order

SPLIT-60 Split Core Current Transformer
  • 60A. Max Split-Core CT is the standard CT. One SPLIT-60 is included in the ECM-1220 PKG. For most 240V split-phase loads, a second SPLIT-60 is required, for loads of 60 A. or less.

  • OUTPUT: 333mV @ 60A

  • TERMINATION: 3.5mm stereo phone plug, tip (+), ring (-), sleeve NC.

  • CABLE:  Between 5 and 6 Feet

  • ACCURACY: +/- 1% from 5A to 55A

NOTE: The SPLIT-60 is NOT compatible with models ECM-1200, ECM-400, ECM-200si, ECM-200B and ECM-200. These units use CT-60 current transformer which is available as a special order. Quantity is limited.

SPLIT-100 Split Core Current Transformer
  • 100 Amp Split Core CT is ideal for permanent or long term monitoring of 100A service panels or loads.
  • The split core type CT is preferred over the clamp-on style for permanent installations because of its size and lower cost.
  • OUTPUT: 333mV @ 100A
  • TERMINATION: 3.5mm stereo phone plug, tip (+), ring (-), sleeve NC.
  • CABLE:  3 Feet, 300V Rating
  • ACCURACY: See CT-200 Specification Sheet Graph
SPLIT-200 Split Core Current Transformer
  • 200 Amp Split Core CT is ideal for permanent or long term monitoring of 200A service panels or loads.
  • The split core type CT is preferred over the clamp-on style for permanent installations because of its size and lower cost.
  • OUTPUT: 333mV @ 200A
  • TERMINATION: 3.5mm stereo phone plug, tip (+), ring (-), sleeve NC.
  • CABLE:  3 Feet, 300V Rating
  • ACCURACY: see Specification Sheet

SPLIT-200 Specifications

CLAMP-100 Clamp-On Current Transformer
  • 100 Amp Clamp-On CT is ideal for field applications where various loads are to be monitored. Because of its design, the CLAMP-100 is much easier to install and remove than the split -core type CT.
  • OUTPUT: 333mV @ 100A
  • TERMINATION: 3.5mm stereo phone plug, tip (+), ring (-), sleeve NC.
  • CABLE:  6 Feet, 300V Rating
  • ACCURACY: see Specification Sheet

CLAMP-100 Specifications

CLAMP-200 Clamp-On Current Transformer
  • 200 Amp Clamp-On CT is ideal for field applications where various "hi current" loads are to be monitored. Because of its design, the CLAMP-200 is much easier to install and remove than the split-core type CT.
  • Not recommended for low current application due to decreased accuracy at low current.
  • OUTPUT: 333mV @ 200A
  • TERMINATION: 3.5mm stereo phone plug, tip (+), ring (-), sleeve NC.
  • CABLE:  6 Feet, 300V Rating
  • ACCURACY: see Specification Sheet

 

DONUT-200 Toroid (donut style) CT:
  • 200A CT
  • unlike the "split-core" and "clamp-on" style CTs, the "donut style" CT requires disconnection of load wire so that it can be threaded through the center of the CT.
  • Generally only for permanent installation.
  • Very accurate
MODEL (no yet determined)

CT "series connecting" Y splitter for connecting two matching CTs to one channel. For 333mV CTs only

Comming

Soon

MODEL (no yet determined)
  • 6ft extension for CTs
VC-100 Voltage Converter
  • This voltage converter is used for certain 240V applications. It is used to power the wall transformer in situations where no 120V access is available.
  • INPUT: 240VAC
  • OUTPUT: 120VAC
DCC-1 Deluxe Carrying Case
  • Blue polypropylene/nylon  with foam insert
  • Metal Core Hinges
  • Nylon Latches
  • 12.75" x 9.25" x 4.56" (324mm x 235mm x 116mm)

 

 

BCC-1 Basic Carrying Case
  • Blue polypropylene on with foam insert
  • 12.75" x 9.25" x 2.625" (324mm x 235mm x 67mm)

 

MODEL (no yet determined)
  • Additional Memory Storage "IC chips"
  • Must be installed at the factory.
  • Available in increments of additional 13,107 records
  • Maximum memory: 52,401 records
U2Z USB to Zigbee Dongle
  • An additional Dongle is available to provide a second computer access to ECM-1220 -X models.
  • Also performs "routing" function to provide mesh network "hopping".
 

 

  ©Brultech Research Inc